Test 2016-07-25-11-5 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 210959
DEA: 08465524
EFIS: 0815000118
MINOR: 08A2540
DIST-CO-RTE-PM08-RIV-74-16.1/71.8
Work DescriptionCONSTRUCTION ON STATEƃ ? HIGHWAY IN VARIOUS CITIES, ROUTES AND POST MILES IN RIVERSIDE COUNTY.
Location DescriptionVarious locations in Riverside County
Sample Information
Sample Taken Date7/25/2016 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/28/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byRussel Last name of sampler or witnessed byLynch
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameTNT Rebar Nucor Transportation Laboratory (TL) NumberC952650
Inspector Lot Number from the Transportation Laboratory (TL) FormL9607416 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL1410777
Hoop Manufacturer Lot Number(s)1, 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2016-07-25-11
DIME Test ID: 2016-07-25-11-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-08-01
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/29/2016
UTM:400KIP
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
112#4/13mm0.21802090100Bar Broke in Heat Affected AreaFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke in Heat Affected Area; NO Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 08/01/2016