Summary for Test 2016-07-21-12-1

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Award Date11/27/2012
Closeout DateNot set
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
QA Service Level1 (Verified on 10/29/2012)

Sample Information

Sample Taken Date07/21/2016 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/22/2016
Sample typeQuality Assurance A brief description of the sampleEnd Anchors
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHRC CMC Rebar Transportation Laboratory (TL) NumberC731310
Inspector Lot Number from the Transportation Laboratory (TL) FormL5301716 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4057340 Head Manufacturer Lot Number(s)17
Rebar Size#7 Headed Bar Model Name120T
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Rebar
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2016-07-21-12
DIME Test ID: 2016-07-21-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2016-07-26

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/26/2016
UTM: 400KIP
Temperature: 72 F
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
1170.661620102700Bar Broke in WeldFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke in Weld; No Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/26/2016