Test 2016-05-19-8-1 (CONCLP 1-16) Summary

Project Information
Project IdentifiersProject ID: 210756
DEA: 043G4034
EFIS: 0412000101
DIST-CO-RTE-PM04-CC,SOL-80-13.4/14.1,0.0/0.6
Work DescriptionRESURFACE BRIDGE , INSTALL NEW JOINT SEAL..
Location DescriptionIN CONTRA COSTA AND SOLANO COUNTIESON THE CARQUINEZ BRIDGE (1958)
Sample Information
Sample Taken Date5/19/2016 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/19/2016
Sample typeQuality Control A brief description of the samplepolyester resin
The quantity of what the sample constitutes40000 lbs From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility namereichhold Transportation Laboratory (TL) Numberc240494
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypePolyester Mfg. Lot Number(s)0000975313
Batch number0000975313 Mix number
Test Details
DIME Sample ID: 2016-05-19-8
DIME Test ID: 2016-05-19-8-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 1-16: Polyester Resin Patching Materials
Test Release Date: 2016-07-15
Test Results

Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 07/15/2016
Sand Type: b-11
Sand Percent: 67 %
Sand Weight: 3632 g
Aggregate Type: s-39
Aggregate Percent: 33 %
Aggregate Weight: 1916 g
Resin Percent: 12 %
Resin Weight: 654 g
MEKP Percent: 2 %
MEKP Weight: 13.1 g
Time Started: 0940
Test 1 psi: 457
Test 2 psi: 507
Test 3 psi: 446
Average psi:470
General comments (publicly viewable) (Max 1000 characters): retest 1-469 2-575 3-519

Test was verified on 07/15/2016