Test 2016-07-08-13-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
Sample Information
Sample Taken Date7/8/2016 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/13/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed bySantos Last name of sampler or witnessed byVargas
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) NumberC952719
Inspector Lot Number from the Transportation Laboratory (TL) FormL10001516 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)4055846
Hoop Manufacturer Lot Number(s)41 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop4'-10.25" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2016-07-08-13
DIME Test ID: 2016-07-08-13-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-07-14
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/14/2016
UTM:400KIP
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1241#5/16mm0.312847091840Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 07/14/2016