Summary for Test 2016-06-07-19-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 209918
DEA: 07274804
EFIS: 0700000516
DIST-CO-RTE-PM07-LA-18-0.2
Award Date12/09/2014
Closeout Date01/15/2018
Work DescriptionREPLACE BRIDGE DECK AND RAILING, REPAIR BENT CAPS AND COLUMNS.
Location DescriptionLOS ANGELES COUNTY AT LLANO AT COUNTY LINE OVERHEAD
QA Service Level1 (Verified on 01/08/2015)

Sample Information

Sample Taken Date06/07/2016 Sample Unique Key19
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/09/2016
Sample typeAnnual Source Testing A brief description of the sampleThree eights inch PCC Aggregates
The quantity of what the sample constitutes4 Bags From where was the sample collectedSource
First name of sampler or witnessed byStefan Last name of sampler or witnessed byReder
Title of samplerQA Manager Telephone number of samplerUnknown
Laboratory sample identification6238B Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHi Grade Materials Company Littlerock Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)SMARA 91 19 0026
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2016-06-07-19
DIME Test ID: 2016-06-07-19-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-10-15

Test Results


What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Babak Razaei
Date of test: 06/27/2016
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 94 %
Cumulative percent passing the #4 sieve: 16 %
Cumulative percent passing the #8 sieve: 4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/15/2019