Summary for Test 2016-05-20-8-3

Test performed: ASTM D3278-Jan96

Project Information

Project IdentifiersProject ID: 211208
DEA: 120N9604
EFIS: 1215000014
DIST-CO-RTE-PM12-ORA-5,90,91,241,405-var
Award Date04/22/2016
Closeout Date10/24/2016
Work DescriptionMETHACRYLIC TREATMENT AND JOINT SEAL REPLACEMENT
Location DescriptionNot set
QA Service Level1 (Verified on 06/20/2016)

Sample Information

Sample Taken Date05/20/2016 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/24/2016
Sample typeQuality Assurance A brief description of the samplesample for 25000 gallons
The quantity of what the sample constitutes2 pints can From where was the sample collectedManufacturer
First name of sampler or witnessed bymanufacture Last name of sampler or witnessed bysubmitted
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namekwik Bond, Benecia Transportation Laboratory (TL) NumberC240495
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)16-061
Batch number1606666766 Mix number3184

Test Details

DIME Sample ID: 2016-05-20-8
DIME Test ID: 2016-05-20-8-3
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D3278-Jan96: Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus
Test Release Date: 2018-09-18

Test Results


Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 06/28/2016
Whether sample flashed and Test Method A was used: yes
Mean of duplicate determinations and Test Method B was used: no
General comments (publicly viewable) (Max 1000 characters): greater than 180