Summary for Test 2016-05-20-8-3
Test performed: ASTM D3278-Jan96Project Information
Project Identifiers | Project ID: 211208 DEA: 120N9604 EFIS: 1215000014 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5,90,91,241,405-var |
Award Date | 04/22/2016 |
Closeout Date | 10/24/2016 |
Work Description | METHACRYLIC TREATMENT AND JOINT SEAL REPLACEMENT |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/20/2016) |
Sample Information
Sample Taken Date | 05/20/2016 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/24/2016 |
Sample type | Quality Assurance | A brief description of the sample | sample for 25000 gallons |
The quantity of what the sample constitutes | 2 pints can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | manufacture | Last name of sampler or witnessed by | submitted |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | kwik Bond, Benecia | Transportation Laboratory (TL) Number | C240495 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | 16-061 |
---|---|---|---|
Batch number | 1606666766 | Mix number | 3184 |
Test Details
DIME Sample ID: 2016-05-20-8
DIME Test ID: 2016-05-20-8-3
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D3278-Jan96: Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus
Test Release Date: 2018-09-18
Test Results
Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 06/28/2016
Whether sample flashed and Test Method A was used: yes
Mean of duplicate determinations and Test Method B was used: no
General comments (publicly viewable) (Max 1000 characters): greater than 180
Test was verified on 9/18/2018 ✔