Summary for Test 2016-06-10-14-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 209576
DEA: 11263304
EFIS: 1100000743
DIST-CO-RTE-PM11-IMP-8-R38.8/R39.1
Award Date07/30/2014
Closeout Date04/09/2018
Work DescriptionBRIDGE REPLACEMENT AND MODIFY INTERCHANGE.
Location DescriptionIMPERIAL COUNTY IN EL CENTRO FROM 0.2 MILE WEST TO 0.1 MILE EAST OF DOGWOOD ROAD OVERCROSSING
QA Service Level1 (Verified on 11/11/2014)

Sample Information

Sample Taken Date06/10/2016 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/22/2016
Sample typeQuality Assurance A brief description of the sampleLenton Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byMichael Last name of sampler or witnessed byNghyen
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification1 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rbar Transportation Laboratory (TL) NumberC384238
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerErico Intermediate Assembler or FabricatorCMC Rebar
Rebar Size#11 Coupler ModelLenton
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)L8755 Rebar Heat Number(s)4055184
Rebar Size 2 NA Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-06-10-14
DIME Test ID: 2016-06-10-14-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-06-23

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/23/2016
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#11/36mm1.56014141290649Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
WARNING: No graph data imported from Instron machine.

Test was verified on 6/23/2016