Summary for Test 2016-06-01-4-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210627
DEA: 074T6104
EFIS: 0712000200
MINOR: 07A3409
DIST-CO-RTE-PM07-LA-101-16.7
Award Date05/11/2015
Closeout Date06/16/2021
Work DescriptionCONSTRUCT CURB RAMPS AND MODIFY SIGNAL AND LIGHTING
Location DescriptionIN LOS ANGELES COUNTY IN LOS ANGELES AT SEPULVEDA BOULEVARD OFF RAMP.
QA Service Level1 (Verified on 07/24/2015)

Sample Information

Sample Taken Date06/01/2016 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/01/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed bySherri Last name of sampler or witnessed byBrannon
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) NumberC953316
Inspector Lot Number from the Transportation Laboratory (TL) FormL4806816 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateService Rebar Heat Number(s)4028299
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerTNT Rebar
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-06-01-4
DIME Test ID: 2016-06-01-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-06-08

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/03/2016
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#5/16mm0.313060098710Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 6/8/2016