Summary for Test 2016-05-31-1-3
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 210040 DEA: 04297624 EFIS: 0400020581 COOP: 042558 |
---|---|
DIST-CO-RTE-PM | 04-ALA-84-22.9/25.7 |
Award Date | 09/30/2015 |
Closeout Date | 03/12/2020 |
Work Description | WIDENING AND EXPRESSWAY UPGRADES |
Location Description | ON ROUTE 84, FROM RUBY HILL DRIVE TO NORTH OF CONCANNON BOULEVARD |
QA Service Level | 1 (Verified on 11/10/2015) |
Sample Information
Sample Taken Date | 05/31/2016 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/01/2016 |
Sample type | Quality Assurance | A brief description of the sample | Headed Bars |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Harris Salinas | Transportation Laboratory (TL) Number | C741280 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B1024516 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Rebar Heat Number(s) | SE16100975 | Head Manufacturer Lot Number(s) | NA |
Rebar Size | #11 | Headed Bar Model Name | HRC 555 |
Size of Head | Reduced Size - 4x | Head Connection Type | Forged |
Head Shape | Circular | Rebar Manufacturer | Harris Salinas |
Head Manufacturer | HRC | Head Fabricator | HRC |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2016-05-31-1
DIME Test ID: 2016-05-31-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2016-06-02
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/02/2016
UTM: 400KIP
Temperature: 72 F
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1.56 | 148600 | 95260 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 6/2/2016 ✔