Summary for Test 2016-05-17-12-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211035 Permit Numbers: 0915NSN0117 0915NDP0265 |
---|---|
DIST-CO-RTE-PM | 09-KER--94.164/94.277 |
Award Date | 07/31/2015 |
Closeout Date | 10/28/2019 |
Work Description | Construct the East Tehachapi Traffic Signal and Street Improvements Project as shown on the attached plans. |
Location Description | Tehachapi Blvd, Tehachapi |
QA Service Level | 1 (Verified on 11/19/2015) |
Sample Information
Sample Taken Date | 05/17/2016 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/23/2016 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | C952968 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | C952968 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Service | Rebar Heat Number(s) | 002116 |
Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 5 |
Diameter of Hoop | 2'-8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2016-05-17-12
DIME Test ID: 2016-05-17-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-05-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/24/2016
UTM: 75KIP
Temperature: 70 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | 5 | 0.31 | 29129 | 93960 | necking okay | Fred |
General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
WARNING: No graph data imported from Instron machine.