Test 2016-03-24-11-1 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 208714
DEA: 08043514
EFIS: 0800000010
DIST-CO-RTE-PM08-SBD-58-R22.2/R31.1
Work DescriptionREALIGN AND WIDEN 2 TO 4 LANES EXPRESSWAY
Location DescriptionHINKLEY ROAD FROM 2.4 MILES WEST OF HIDDEN RIVER ROAD TO? 0.7 MILE EAST OF LENWOOD ROAD.
Sample Information
Sample Taken Date3/24/2016 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/1/2016
Sample typeAnnual Source Testing A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes6 Bags From where was the sample collectedSource
First name of sampler or witnessed byStefan Last name of sampler or witnessed byReder
Title of samplerQC Manager Laboratory sample identification6112B
The fabricator/manufacturer/facility nameHi Grade Lucern Valley Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)SMARA 91 36 0042
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design number Lot numberNot set
Sublot numberNot set HMA Design ID
Test Details
DIME Sample ID: 2016-03-24-11
DIME Test ID: 2016-03-24-11-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-10-15
Test Results

What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Friday Ofoegbu
Date of test: 04/16/2016
Cumulative percent passing the 3/8 in. sieve:100 %
Cumulative percent passing the #4 sieve:100 %
Cumulative percent passing the #8 sieve:79 %
Cumulative percent passing the #16 sieve:52 %
Cumulative percent passing the #30 sieve:31 %
Cumulative percent passing the #50 sieve:17 %
Cumulative percent passing the #100 sieve:8 %
Cumulative percent passing the #200 sieve:4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/15/2019