Summary for Test 2016-04-19-5-3

Test performed: ASTM D412-06a-re13

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/19/2016 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/26/2016
Sample typeQuality Assurance A brief description of the sampleJoint Seal
The quantity of what the sample constitutes300ft From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed bySimon
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameD S Brown Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM2 - Type B Elastomeric Joint Seal Mfg. Lot Number(s)0716198
Manufacturer(s)D S Brown Temperature72
Humidity50 CommentsUnknown
Joint Seal Size5in

Test Details

DIME Sample ID: 2016-04-19-5
DIME Test ID: 2016-04-19-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Test Release Date: 2016-05-03

Test Results


Number of specimens tested: 3
Unit of the Ultimate Tensile Values: psi
Input Type: Calculated
Tester's full name: Brian
Date of test: 04/27/2016
UTM: 2KIP
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness: 0.067 in
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2678.6 lbf?in/in?
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.07 in
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 2514.3 lbf?in/in?
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.067 in
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2619 lbf?in/in?
Sample 3 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2619 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Sample 1

Source: Partner Data Point File
Test graph for Sample 2

Source: Partner Data Point File
Test graph for Sample 3

Test was verified on 5/3/2016