Test 2016-04-06-7-3 (ASTM D412-06a-re13) Summary

Project Information
Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Work Description
Location Description
Sample Information
Sample Taken Date4/6/2016 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/7/2016
Sample typeQuality Assurance A brief description of the sampleJoint Seal
The quantity of what the sample constitutes550ft From where was the sample collectedSource
First name of sampler or witnessed byDavid Last name of sampler or witnessed bySimon
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameWatson Bowman Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM2 - Type B Elastomeric Joint Seal Mfg. Lot Number(s)0516190
Manufacturer(s)Watson Bowman Temperature72
Humidity50 CommentsUnknown
Joint Seal Size3.75in
Test Details
DIME Sample ID: 2016-04-06-7
DIME Test ID: 2016-04-06-7-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension
Test Release Date: 2016-04-20
Test Results

Input Type: Calculated
Tester's full name: Brian
Date of test: 04/13/2016
UTM: 2KIP
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness:0.073 in
Sample 1 Thickness all Within 0.003 inch?:Yes
Sample 1 Ultimate Tensile:2459 lbf?in/in?
Sample 1 Elongation (350% Min):Pass
Sample 2 Median Thickness:0.07 in
Sample 2 Thickness all Within 0.003 inch?:Yes
Sample 2 Ultimate Tensile:2514.3 lbf?in/in?
Sample 2 Elongation (350% Min):Pass
Sample 3 Median Thickness:0.079 in
Sample 3 Thickness all Within 0.003 inch?:Yes
Sample 3 Ultimate Tensile:2424.2 lbf?in/in?
Sample 3 Elongation (350% Min):Pass
Median of the Ultimate Tensile Values:2459 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Sample 1

Source: Partner Data Point File
Test graph for Sample 2

Source: Partner Data Point File
Test graph for Sample 3

Test was verified on 04/20/2016