Summary for Test 2016-03-14-2-2

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 210737
DEA: 073X7114
EFIS: 0715000132
DIST-CO-RTE-PM07-LA-60,126-R7.4/R8.1
Award Date11/16/2015
Closeout Date06/16/2021
Work DescriptionREALIGN RAMPS, WIDEN BRIDGE, AND REPLACE RAMPS PAVEMENT.
Location DescriptionIN LA COUNTY, IN CITY OF MONTEBELLOAT PARAMOUNT BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 12/11/2015)

Sample Information

Sample Taken Date03/14/2016 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/16/2016
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byJohn Last name of sampler or witnessed byLee
Title of samplerStructure Representative Telephone number of samplerUnknown
Laboratory sample identification929-94 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namePlant Transportation Laboratory (TL) Number1269494
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberS62578
The truck number from where the sample was collected361 The batch plant ticket number from where the sample was collected1269494
Concrete batch plantUnknown The fabricator/manufacturer designation for the samplePlant
A detailed description of where the material sample was collectedBatch Plant Where the material sample would have been placed if not sampled60 Paramount WB off Ramp
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-03-14-2
DIME Test ID: 2016-03-14-2-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-04-11

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 04/11/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 109400 lb
Maximum load on cylinder 2: 109090 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 3894.6 psi
Compressive strength of cylinder 2: 3883.6 psi
Compressive strength (to nearest 10 psi): 3890 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/11/2016