Summary for Test 2016-03-15-7-2
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/15/2016 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/22/2016 |
Sample type | Quality Assurance | A brief description of the sample | .6in Prestressing Strand |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | Unknown |
---|---|---|---|
Reel/Coil/Pack Number(s) | S333148-6-1, S333498-5-1, S333516-2-1, S333529-5-1, S333531-2-1, S333532-3-1, S333554-1-1 | Number of Coils | Unknown |
Group Number | 10843 | Strand Diameter | |
Grade | 270 | Strand Specification | ASTM A 882 |
Heat Number(s) | S0591314-2, S0556815, S0556715, S0592215, S0544815-2, S0544615 | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2016-03-15-7
DIME Test ID: 2016-03-15-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2016-03-24
Test Results
Number of Samples: 7
Input Type: Calculated
Tester's full name: Brian
Date of test: 03/24/2016
UTM: 120KIP
Temperature: 70 F
Extensometers: E88766
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | SO591314-2 | S333148-6-1 | 0.213 | 59666 | 54615 | 28.4 | 1.61 | Brian |
2 | SO556815 | S333498-5-1 | 0.213 | 59069 | 28.5 | 1.75 | Brian | |
3 | SO556715 | S333516-2-1 | 0.214 | 59597 | 27.8 | 1.63 | Brian | |
4 | SO592215 | S333529-5-1 | 0.217 | 60524 | 28.1 | 1.79 | Brian | |
5 | SO544815-2 | S333531-2-1 | 0.215 | 59616 | 27.8 | 1.67 | Brian | |
6 | SO544815-2 | S333532-3-1 | 0.215 | 59150 | 28 | 1.77 | Brian | |
7 | SO544615 | S333554-1-1 | 0.217 | 60118 | 28 | 1.84 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 3/24/2016 ✔