Summary for Test 2021-11-18-18-1
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 215589 DEA: 112N0084 EFIS: 1117000153 |
---|---|
DIST-CO-RTE-PM | 11-IMP-7,8,78,86,98,111-Var |
Award Date | 06/25/2021 |
Closeout Date | 09/14/2023 |
Work Description | METHACRYLATE BRIDGE DECKS, REPAIR SPALLS AND REPLACE JOINT SEALS. |
Location Description | IMPERIAL COUNTY AT VARIOUS LOCATIONS. |
QA Service Level | 1 (Verified on 07/06/2021) |
Sample Information
Sample Taken Date | 11/18/2021 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/18/2021 |
Sample type | Authorization | A brief description of the sample | HMWM |
The quantity of what the sample constitutes | 1 Quart | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Rob | Last name of sampler or witnessed by | Johnson |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Transpo Industries Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | B1102217010 |
---|---|---|---|
Batch number | B1102217010 | Mix number | 3583 |
Test Details
DIME Sample ID: 2021-11-18-18
DIME Test ID: 2021-11-18-18-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2021-12-03
Test Results
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 12/03/2021
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 24.8
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.01
Volatile content (ASTM D 2369) 30% max: 25
Flash point (ASTM D 3828) more than 180 deg F: 211
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: no data
Tack free time, 400 minutes max: 331
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/3/2021 ✔