Test 2016-01-28-10-1 (ASTM C39-17a) Summary

Project Information
Project IdentifiersProject ID: 209139
DEA: 071170U4
EFIS: 0700000085
DIST-CO-RTE-PM07-LA-10-33.2/37.2
Work DescriptionCONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE WEST OF PUENTE AVENUE UNDERCROSSING TO 0.2 MILE EAST OF HOLLENBECK STREET UNDERCROSSING
Sample Information
Sample Taken Date1/28/2016 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/2/2016
Sample typeQuality Control A brief description of the sample6X12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byWALTER Last name of sampler or witnessed byPEREIRA
Title of samplerASR Laboratory sample identification882-15
The fabricator/manufacturer/facility nameCEMEX Transportation Laboratory (TL) Number42169715
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier01M W OF PUENTE AVE UC TO 02M E OF HOLLENBECK ST UC
Structure nameSTA 1799 00 OH SIGN 4C CIDH CONC FND
Material Information
Material TypeConcrete The concrete mix design number1570340
The truck number from where the sample was collected10036918 The batch plant ticket number from where the sample was collected26324404
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedTRUCK Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown
Test Details
DIME Sample ID: 2016-01-28-10
DIME Test ID: 2016-01-28-10-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-02-12
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 02/12/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.97 in
Maximum load on cylinder 1: 99330 lb
Maximum load on cylinder 2: 101730 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 14 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 27.99 in^2
Compressive strength of cylinder 1: 3548.8 psi
Compressive strength of cylinder 2: 3634.5 psi
Compressive strength (to nearest 10 psi):3590 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 02/12/2016