Summary for Test 2021-10-18-41-1

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 214524
DEA: 07304504
EFIS: 0714000067
DIST-CO-RTE-PM07-LA-57-R0.0/R4.5
Award Date06/11/2020
Closeout DateNot set
Work DescriptionCONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK.
Location DescriptionLOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION
QA Service Level1 (Verified on 08/12/2020)

Sample Information

Sample Taken Date10/18/2021 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/19/2021
Sample typePer Request A brief description of the sampleA set of 2 PCC concrete beam test specimens
The quantity of what the sample constitutesPer 1000 CY From where was the sample collectedJob Site
First name of sampler or witnessed byAli Last name of sampler or witnessed byRehman
Title of samplerField Materials Tester Telephone number of sampler(714) 875-3445
Laboratory sample identification212636-07304504-111521 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVanguard at the 57 Freeway Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numbercrcp 570
The truck number from where the sample was collected0 The batch plant ticket number from where the sample was collected3
Concrete batch plantVanguard at 57 Freeway The fabricator/manufacturer designation for the sampleBatch
A detailed description of where the material sample was collectedconcrete sample from wheelbarrow Where the material sample would have been placed if not sampledNB 57 mainline
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-10-18-41
DIME Test ID: 2021-10-18-41-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2021-11-15

Test Results


Number of specimens: 2
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Jeff Diaz
Date of test: 11/15/2021
Identification number: 1
Width of specimen: 6.12 inch
Width of specimen 2: 6.12 inch
Depth of specimen: 6.06 inch
Depth of specimen 2: 6.06 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Maximum load applied: 765 lb
Maximum load applied 2: 750 lb
Curing history and apparent moisture condition of the specimen: 0
If specimen was capped, ground or if leather shims were used: 0
Defects in specimen: 0
Age of specimen: 28 days
Age of specimen in hours: no data
Modulus of rupture: 770 psi
Modulus of rupture 2: 760 psi
Modulus of rupture average: 770 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/15/2021