Summary for Test 2021-10-18-41-1
Test performed: CTM 523-May 2020Project Information
Project Identifiers | Project ID: 214524 DEA: 07304504 EFIS: 0714000067 |
---|---|
DIST-CO-RTE-PM | 07-LA-57-R0.0/R4.5 |
Award Date | 06/11/2020 |
Closeout Date | Not set |
Work Description | CONCRETE PAVEMENT, CONCRETE BARRIER, AND ELECTRICAL WORK. |
Location Description | LOS ANGELES COUNTY IN DIAMOND BAR AND CITY OF INDUSTRY FROM ORANGE COUNTY LINE TO ROUTE 57/60 SEPARATION |
QA Service Level | 1 (Verified on 08/12/2020) |
Sample Information
Sample Taken Date | 10/18/2021 | Sample Unique Key | 41 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/19/2021 |
Sample type | Per Request | A brief description of the sample | A set of 2 PCC concrete beam test specimens |
The quantity of what the sample constitutes | Per 1000 CY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Ali | Last name of sampler or witnessed by | Rehman |
Title of sampler | Field Materials Tester | Telephone number of sampler | (714) 875-3445 |
Laboratory sample identification | 212636-07304504-111521 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vanguard at the 57 Freeway | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | crcp 570 |
---|---|---|---|
The truck number from where the sample was collected | 0 | The batch plant ticket number from where the sample was collected | 3 |
Concrete batch plant | Vanguard at 57 Freeway | The fabricator/manufacturer designation for the sample | Batch |
A detailed description of where the material sample was collected | concrete sample from wheelbarrow | Where the material sample would have been placed if not sampled | NB 57 mainline |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-10-18-41
DIME Test ID: 2021-10-18-41-1
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2021-11-15
Test Results
Number of specimens: 2
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Jeff Diaz
Date of test: 11/15/2021
Identification number: 1
Width of specimen: 6.12 inch
Width of specimen 2: 6.12 inch
Depth of specimen: 6.06 inch
Depth of specimen 2: 6.06 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Maximum load applied: 765 lb
Maximum load applied 2: 750 lb
Curing history and apparent moisture condition of the specimen: 0
If specimen was capped, ground or if leather shims were used: 0
Defects in specimen: 0
Age of specimen: 28 days
Age of specimen in hours: no data
Modulus of rupture: 770 psi
Modulus of rupture 2: 760 psi
Modulus of rupture average: 770 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/15/2021 ✔