Summary for Test 2016-01-22-5-2

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/22/2016 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/28/2016
Sample typeQuality Assurance A brief description of the sample.6in Prestressing Strand
The quantity of what the sample constitutes43 From where was the sample collectedFabricator
First name of sampler or witnessed byDon Last name of sampler or witnessed byHiranaga
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsUnknown
Reel/Coil/Pack Number(s)S333623-2 S333627-2 S333627-5 S333631-5 S333635-5 S333641-3 S333642-1 S333645-3 S333645-4 S333646- 2 S333646-7 S333649- 2 S333652-1 S333653-1 S333653- 2 S333654-2 S333654-3 S377400-3 S377400-5 S377414-4 Number of Coils20
Group Number10838 Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0585015 S0585215 S0584115 S0584515 S0584715 S0584215 S0584615 S0585315 S0595115 S0585115 S0584415 S0584315 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden

Test Details

DIME Sample ID: 2016-01-22-5
DIME Test ID: 2016-01-22-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2016-02-03

Test Results


Number of Samples: 20
Input Type: Calculated
Tester's full name: Brian
Date of test: 02/01/2016
UTM: 120KIP
Temperature: 70 F
Extensometers: E88766
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1SO585015S333623-20.215599305495928.41.76Brian
2SO585215S333627-20.2146043528.51.77Brian
3SO585215S333627-50.2146079728.41.76Brian
4SO584115S333631-50.2146073128.31.84Brian
5SO584515S333635-50.2146091928.71.98Brian
6SO584715S333641-30.2146009828.81.8Brian
7SO584715S333642-10.21460313291.96Brian
8SO584215S333645-30.21460010291.82Brian
9SO584215S333645-40.2145998028.71.82Brian
10SO584615S333646-20.2146011628.51.79Brian
11SO584615S333646-70.2146016229.21.8Brian
12SO585315S333649-20.2146014928.51.78Brian
13SO585315S333652-10.2146052028.61.87Brian
14SO595115S333653-10.2165996028.21.8Brian
15SO595115S333653-20.2165998728.11.73Brian
16SO585115S333654-20.2146045328.31.75Brian
17SO585115S333654-30.2146068528.41.83Brian
18SO584415S377400-30.2166061628.31.71Brian
19SO584415S377400-50.2166020627.41.68Brian
20SO584315S377414-40.2166071627.91.71Brian

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 2/3/2016