Summary for Test 2021-08-12-52-5

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/12/2021 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/01/2021
Sample typePer Request A brief description of the sample3/4" HMA (Drum Plant)
The quantity of what the sample constitutes_ From where was the sample collectedManufacturer
First name of sampler or witnessed byHarish Last name of sampler or witnessed byThakur
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2021-08-12-42
The fabricator/manufacturer/facility nameGranite Pleasanton Transportation Laboratory (TL) Number21-JMF-0190
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0009
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-08-12-52
DIME Test ID: 2021-08-12-52-5
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2021-11-10

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Bang Nguyen
Date of test: 11/04/2021
Weighted percentage of particles (by mass) that were flat and elongated: 0 %
Weighted percentage of particles (by mass) that were not flat and elongated: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/10/2021