Summary for Test 2016-01-12-2-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 208967 DEA: 110223U4 EFIS: 1112000102 |
---|---|
DIST-CO-RTE-PM | 11-SD-5,89-R29.1/R30.5 |
Award Date | 12/18/2014 |
Closeout Date | 02/04/2022 |
Work Description | REPLACE AND WIDEN BRIDGE, RECONSTRUCT RAMPS AND INTERSECTION. |
Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE SOUTH OF GENESEE AVENUE OVERCROSSING TO SORRENTO VIADUCT |
QA Service Level | 1 (Verified on 01/21/2015) |
Sample Information
Sample Taken Date | 01/12/2016 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/15/2016 |
Sample type | Quality Assurance | A brief description of the sample | Coupon Casting |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Debbie | Last name of sampler or witnessed by | Ozuna |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | DSI | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | BCI | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | 11195 2 |
---|---|---|---|
Part Number (s) | 68 27 216 246 | Material Specification | A536 |
Grades | 65-45-12 | Metal Foundry Manufacturer (Mill) | BCI |
Prestressing Manufacturer | DIS |
Test Details
DIME Sample ID: 2016-01-12-2
DIME Test ID: 2016-01-12-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2016-01-26
Test Results
Number of Samples: 2
Input Type: Calculated
Tester's full name: Fred
Date of test: 01/18/2016
UTM: 67KIP
Temperature: 71 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 11195 2 | 0.496 | 0.1932 | 68634 | 116530 | 6.9 | Fred | |
2 | 11195 2 | 0.496 | 0.1932 | 66214 | 114050 | 9.8 | Fred |
General comments (publicly viewable) (Max 1000 characters): Elongation test is invalid, samples broke at gage length punch marks.
Test Graph
Test was verified on 1/26/2016 ✔