Test 2021-09-20-61-2 (AASHTO T315-20) Summary

Project Information
Project IdentifiersProject ID: 215638
DEA: 09387904
DIST-CO-RTE-PM09-INY-190-111.6/126.1
Work DescriptionPLACE HMA OVER EXISTING PAVEMENT.
Location DescriptionINYO COUNTY NEAR FURNACE CREEK FROM 0.1 MILE WEST OF BAD WATER ROAD TO 3.6 MILES EAST OF DANTE'S VIEW ROAD
Sample Information
Sample Taken Date9/20/2021 Sample Unique Key61
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/25/2021
Sample typeAcceptance A brief description of the sampleTEST Asphalt Binder, NO TEST 9/21, 9/22, 9/23
The quantity of what the sample constitutes2 CANS From where was the sample collectedSource
First name of sampler or witnessed byWULFENSTEIN Last name of sampler or witnessed byWULFENSTEIN
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameErgon Transportation Laboratory (TL) Number995107
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 70-10
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Asphalt Binder SupplierErgon Asphalt & Emulsions Incorporated - Las Vegas NV MultigradeNo
Multigrade Type HMA Design ID
Test Details
DIME Sample ID: 2021-09-20-61
DIME Test ID: 2021-09-20-61-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-11-05
Test Results

Phase: RTFO residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 11/03/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.264 kPa
Phase Angle (δ) (for the 10 cycles): 85.6 degree
Complex Modulus (G*) (for the 10 measurements): 2.645 kPa
Test Temperature (Specimen 1): 70.0 C
Dynamic Shear, G*/sin(δ): 2.65 kPa
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specifications RTFO

Test was verified on 11/05/2021