Summary for Test 2021-10-15-9-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212252 DEA: 033F5604 EFIS: 0313000033 |
---|---|
DIST-CO-RTE-PM | 03-SUT,YUB-20-17.0/17.1,0.0/0.4 |
Award Date | 02/11/2021 |
Closeout Date | 01/25/2023 |
Work Description | INSTALL CAST-IN-STEEL SHELL CONCRETE PILE. |
Location Description | SUTTER AND YUBA COUNTIES IN YUBA CITY AND MARYSVILLE AT THE FEATHER RIVER BRIDGE AND OVERHEAD |
QA Service Level | 1 (Verified on 04/27/2018) |
Sample Information
Sample Taken Date | 10/15/2021 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/18/2021 |
Sample type | Quality Assurance | A brief description of the sample | #14 HRC 500/510 Couplers |
The quantity of what the sample constitutes | 150 Couplers | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kareh | Last name of sampler or witnessed by | Aladini |
Title of sampler | ASR | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CN Reinforcing Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Cascade Steel |
Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | |
Rebar Size | #14 | Coupler Model | HRC 500/510 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | 73118000 73121211 | Rebar Heat Number(s) | 213421 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2021-10-15-9
DIME Test ID: 2021-10-15-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2021-10-26
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: She Vang
Date of test: 10/22/2021
UTM: NA
Halo ID: Kleinfelder Lab
Temperature: 73 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | #14 | 2.25 | 0.020 | 210970 | 94000 | visible necking, fracture on bar | K DeSouza |
2 | 2 | 1 | #14 | 2.25 | 0.020 | 210810 | 93500 | visible necking, fracture on bar | K DeSouza |
3 | 3 | 1 | #14 | 2.25 | 0.020 | 204320 | 91000 | visible necking, fracture on bar | K DeSouza |
4 | 4 | 1 | #14 | 2.25 | 0.020 | 220490 | 98000 | visible necking, fracture in affected zone | K DeSouza |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/26/2021 ✔