Summary for Test 2021-09-20-54-3

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 215414
DEA: 101J2104
EFIS: 1018000144
DIST-CO-RTE-PM10-SJ-99-9.4/15.0
Award Date02/23/2021
Closeout Date08/26/2022
Work DescriptionPLACE RHMA, COLD PLANE ASPHALT CONCRETE, TRAFFIC STRIPING.
Location DescriptionSAN JOAQUIN COUNTY IN AND NEAR STOCKTON FROM 0.2 MILE NORTH OF LATHROP ROAD OVERCROSSING TO 0.3 MILE NORTH OF ARCH ROAD UNDERCROSSING
QA Service Level1 (Verified on 02/01/2021)

Sample Information

Sample Taken Date09/20/2021 Sample Unique Key54
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/07/2021
Sample typeAcceptance A brief description of the samplePG 64-16
The quantity of what the sample constitutes1 can, NO TEST 9/27, 9/29 From where was the sample collectedSupplier
First name of sampler or witnessed byJ Last name of sampler or witnessed byKort
Title of samplerInspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Materials Vernalis Transportation Laboratory (TL) Number21M6416-920
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierMarathon Petroleum Co. LP - Elk Grove CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-09-20-54
DIME Test ID: 2021-09-20-54-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-10-22

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 10/14/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 39.431 kPa
Phase Angle (δ) (for the 10 cycles): 52.1 degree
Complex Modulus (G*) (for the 10 measurements): 3942.624 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 3111 kPa
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specifications PAV

Test was verified on 10/22/2021