Test 2021-10-06-16-5 (AASHTO T315-20) Summary

Project Information
Project IdentifiersProject ID: 215348
DEA: 060U4204
EFIS: 0616000004
DIST-CO-RTE-PM06-FRE-99-R4.9/11.6
Work DescriptionCONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location DescriptionFRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
Sample Information
Sample Taken Date10/6/2021 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/8/2021
Sample typeAcceptance A brief description of the samplebinder
The quantity of what the sample constitutes1 can From where was the sample collectedSource
First name of sampler or witnessed byunknown Last name of sampler or witnessed byUnknown
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameSan Joaquin Refinery Transportation Laboratory (TL) Number040246
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 70-10
Modified Lot number2
Sublot number7 Tank number
Time of sample HMA SupplierVulcan Materials
Asphalt Binder SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type HMA Design ID
Test Details
DIME Sample ID: 2021-10-06-16
DIME Test ID: 2021-10-06-16-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-10-22
Test Results

Phase: RTFO residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 10/20/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.217 kPa
Phase Angle (δ) (for the 10 cycles): 88.9 degree
Complex Modulus (G*) (for the 10 measurements): 2.173 kPa
Test Temperature (Specimen 1): 70.0 C
Dynamic Shear, G*/sin(δ): 2.17 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 standard specifications

Test was verified on 10/22/2021