Test 2021-10-06-25-5 (CTM 518-June 2010) Summary

Project Information
Project IdentifiersProject ID: 213707
DEA: 081C38U4
EFIS: 0817000196
DIST-CO-RTE-PM08-RIV-10-6.7/R25.1
Work DescriptionRemove concrete pavement and base, and place HMA and JPCP
Location DescriptionROUTE 10/60 SEPARATION IN BEAUMONT TO ROUTE 10/111 SEPARATION NEAR CABAZON.
Sample Information
Sample Taken Date10/6/2021 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/7/2021
Sample typeQuality Assurance A brief description of the sampleJPCP beams
The quantity of what the sample constitutes4 Beams From where was the sample collectedJob Site
First name of sampler or witnessed byFernando, James Last name of sampler or witnessed byCarranza, Burton
Title of sampler Laboratory sample identification118JA1,118JA2,118JB1, 118JB2
The fabricator/manufacturer/facility nameCoffman Specialties, Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeConcrete The concrete mix design number1906-2
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedTTI
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedOn Job Site at Concrete Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.
Test Details
DIME Sample ID: 2021-10-06-25
DIME Test ID: 2021-10-06-25-5
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Test Release Date: 2021-10-18
Test Results

Input Type: Calculated
Tester's full name: F. Carranza/J. Burton
Date of test: 10/16/2021
Calibration factor: 2
Weight of (Measure + Concrete + Cover Plate): 94.65 lb
Weight of (Measure + Cover Plate): 22.3 lb
Total weight of cement: 4430 lb
Total weight of fine aggregate: 11600 lb
Total weight of coarse aggregate: 18480 lb
Total weight of water added during mixing: 1927.8 lb
Kelly Ball Penetration of the batch of concrete tested: 1.25 inch
Air content by the pressure method: 5.5 %
Station number or portion of the structure in which the concrete was placed: 454+00
Volume of the concrete: 9.71 yd^3
Unit weight of the concrete:144.7 lb/ft^3
Cement content:609.5 lb/yd^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/18/2021