Test 2021-10-05-36-5 (CTM 518-June 2010) Summary

Project Information
Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
Sample Information
Sample Taken Date10/5/2021 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/6/2021
Sample typeAcceptance A brief description of the sampleConcrete beams
The quantity of what the sample constitutes4 Beams From where was the sample collectedJob Site
First name of sampler or witnessed byNathan / Zachariah Last name of sampler or witnessed byOgbasellasie/ Roush
Title of sampler Laboratory sample identification2JA1, 2JA2, 2JB1, 2JB2
The fabricator/manufacturer/facility nameCemex, Fontana Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeConcrete The concrete mix design number1605762
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedTTI
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedOn Job Site at Concrete Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.
Test Details
DIME Sample ID: 2021-10-05-36
DIME Test ID: 2021-10-05-36-5
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Test Release Date: 2021-10-18
Test Results

Input Type: Calculated
Tester's full name: N. Ogbasellasie/ Z. Roush
Date of test: 10/05/2021
Calibration factor: 2
Weight of (Measure + Concrete + Cover Plate): 95.25 lb
Weight of (Measure + Cover Plate): 22.3 lb
Total weight of cement: 4145 lb
Total weight of fine aggregate: 13360 lb
Total weight of coarse aggregate: 18440 lb
Total weight of water added during mixing: 2000.4 lb
Kelly Ball Penetration of the batch of concrete tested: 1.75 inch
Air content by the pressure method: 1.8 %
Station number or portion of the structure in which the concrete was placed: 2219+70
Volume of the concrete: 10.09 yd^3
Unit weight of the concrete:145.9 lb/ft^3
Cement content:588.7 lb/yd^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/18/2021