Test 2021-10-13-12-1 (ASTM C173-16) Summary

Project Information
Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Sample Information
Sample Taken Date10/13/2021 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/13/2021
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byJohn Last name of sampler or witnessed byO'Mara
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameFabricator Name Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeConcrete The concrete mix design numberG3-15-590-3600
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected0
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedOrr and Day Stage 2 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.
Test Details
DIME Sample ID: 2021-10-13-12
DIME Test ID: 2021-10-13-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM C173-16: Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method
Test Release Date: 2021-10-14
Test Results

Input Type: Measured
Tester's full name: John OMara
Date of test: 10/14/2021
Volume of isopropyl alcohol added: 30 oz
Initial meter reading: 6 %
Number of calibrated cups of water added to final meter reading: 1 cups
Final meter reading: 5 %
Correction factor: 0.75
Air content:5.25 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/14/2021