Test 2021-10-05-13-2 (ASTM C39-18) Summary

Project Information
Project IdentifiersProject ID: 209820
DEA: 04297634
EFIS: 0415000040
COOP: 042548
DIST-CO-RTE-PM04-ALA-84,680-17.9/21
Work DescriptionROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION.
Location DescriptionALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84
Sample Information
Sample Taken Date10/5/2021 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/6/2021
Sample typeQuality Control A brief description of the sampleDry Cast concrete sample
The quantity of what the sample constitutes8 Cylinders From where was the sample collectedManufacturer
First name of sampler or witnessed byWally Last name of sampler or witnessed byBucaneg
Title of samplerQC Technician Laboratory sample identification10-5-2021
The fabricator/manufacturer/facility nameForterra Pipe and Precast, Florin Rd Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameDrainage System W1
Material Information
Material TypeConcrete The concrete mix design numberMIX 5
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNA
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedconveyor belt Where the material sample would have been placed if not sampledBox Culvert
From Lot No. Bag Lot No.
Test Details
DIME Sample ID: 2021-10-05-13
DIME Test ID: 2021-10-05-13-2
Testing Lab: Forterra
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-10-14
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Joe Buckley
Date of test: 10/12/2021
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Maximum load on cylinder 1: 63980 lb
Maximum load on cylinder 2: 66370 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1:12.57 in^2
Cross sectional area of cylinder 2:12.57 in^2
Compressive strength (to nearest 10 psi):5190 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/14/2021