Summary for Test 2021-08-31-16-7

Test performed: ASTM C191-13

Project Information

Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/31/2021 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/31/2021
Sample typeAuthorization A brief description of the samplePLC Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM212104 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandCemex
MillVictorville Type of Cementitious MaterialBlended Cement

Test Details

DIME Sample ID: 2021-08-31-16
DIME Test ID: 2021-08-31-16-7
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2021-11-15

Test Results


Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 09/09/2021
Type of Water Used: Type IV grade reagent water
Initial time of setting: 115 min
Final time of setting: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/15/2021