Summary for Test 2021-08-31-16-4
Test performed: ASTM C109-16aProject Information
Project Identifiers | Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for Cementitious Materials for use in Concrete Authorized Material List (AML) |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 08/31/2021 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/31/2021 |
Sample type | Authorization | A brief description of the sample | PLC Cement |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | na | Last name of sampler or witnessed by | na |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CM212104 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Cemex | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Cementitious | Brand | Cemex |
---|---|---|---|
Mill | Victorville | Type of Cementitious Material | Blended Cement |
Test Details
DIME Sample ID: 2021-08-31-16
DIME Test ID: 2021-08-31-16-4
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2021-11-15
Test Results
Will control cubes be used per ASTM C311?: no
Input Type: Measured
Tester's full name: AV
Date of test: 10/11/2021
Age of specimen: 29 days
The amount of flow : 113 %
The amount of water used : 50.0 %
Compressive strength of 1st specimen : 6199 psi
Compressive strength of 2nd specimen: 5375 psi
Compressive strength of 3rd specimen : 4752 psi
Average Compressive strength (to nearest 10 psi): 0 psi
General comments (publicly viewable) (Max 1000 characters): 28 day test -- All specimens eliminated from the average for being outside allowable limits per Section 14 of ASTM C109. However, all strengths were well above the minimum, so the test meets spec for 7 day strength.
Test Graph
Source: Bluehill Data Point FileSource: Bluehill Data Point File
Source: Bluehill Data Point File
Test was verified on 11/15/2021 ✔