Summary for Test 2021-09-27-6-4

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Award Date05/01/2019
Closeout Date02/22/2024
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date09/27/2021 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/30/2021
Sample typeQuality Assurance A brief description of the sample1-1/4" rocap
The quantity of what the sample constitutes640 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler3854470624
Laboratory sample identificationna Linked DIME Sample IDna
The fabricator/manufacturer/facility nameUniversal Industrial Sales, Inc Transportation Laboratory (TL) Numberna
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-168-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0143208
Heat Number(s)10631690, 75069902, 0122029 Nut Mfg. Lot Number(s)804498
Washer Mfg. Lot Number(s)802526 Bolt SpecificationA325
Bolt Length(s)4-1/2" Nut SpecificationA563-DH
Washer SpecificationF436 FinishMechanical Galvanize
Diameter/Size1-1/4" Bolt Mfg. Lot NumberBM5308
Rocap Test Requirement(s) Lubricant Requirements(s)Wax and Dye

Test Details

DIME Sample ID: 2021-09-27-6
DIME Test ID: 2021-09-27-6-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-10-14

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 10/11/2021
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11804498150592A563fsaylor

General comments (publicly viewable) (Max 1000 characters): A563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/14/2021