Summary for Test 2021-09-22-51-2
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 214964 DEA: 051F9204 EFIS: 0514000075 |
---|---|
DIST-CO-RTE-PM | 05-SCR-9-0.9/7.5 |
Award Date | 02/10/2021 |
Closeout Date | 11/28/2022 |
Work Description | REMOVE AND REPLACE DRAINAGE SYSTEMS. |
Location Description | SANTA CRUZ COUNTY IN AND NEAR SANTA CRUZ AT VARIOUS LOCATIONS FROM 0.4 MILE NORTH OF VERNON STREET TO EL SOLYO HEIGHTS DRIVE |
QA Service Level | 1 (Verified on 08/31/2020) |
Sample Information
Sample Taken Date | 09/22/2021 | Sample Unique Key | 51 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/01/2021 |
Sample type | Acceptance | A brief description of the sample | 64-10 |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Romiza |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Granite Felton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | c748983 | Structure unique identifier | |
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-10 |
---|---|---|---|
Modified | No | Lot number | 1 |
Sublot number | 1 | Tank number | |
Time of sample | HMA Supplier | Granite Felton | |
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-09-22-51
DIME Test ID: 2021-09-22-51-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-10-28
Test Results
Phase: RTFO residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 10/06/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.419 kPa
Phase Angle (δ) (for the 10 cycles): 80.7 degree
Complex Modulus (G*) (for the 10 measurements): 4.194 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 4.25 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications rtfo
Test was verified on 10/28/2021 ✔