Test 2021-09-01-58-9 (AASHTO T313-19) Summary

Project Information
Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date9/1/2021 Sample Unique Key58
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/1/2021
Sample typeQuality Control A brief description of the samplePG70-10 Asphalt Binder
The quantity of what the sample constitutes1 of 2 From where was the sample collectedManufacturer
First name of sampler or witnessed byDon Last name of sampler or witnessed byConner
Title of sampler Sr Asphalt Technician Laboratory sample identification7010210901
The fabricator/manufacturer/facility nameBakersfield, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number7010210901
Sublot number Tank number9001
Time of sample7:20 am HMA Supplier
Asphalt Binder SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type HMA Design ID
Test Details
DIME Sample ID: 2021-09-01-58
DIME Test ID: 2021-09-01-58-9
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T313-19: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2021-10-07
Test Results

Input Type: Calculated
Tester's full name: Don Conner
Date of test: 09/02/2021
Time test started: 10:37:17 HH:MM:SS
Flags issued by software during test: None
Correlation coefficient (R²): 0.999975
Regression coefficient a: no data
Regression coefficient b: no data
Regression coefficient c: no data
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Load at 60.0 s: 0.0 mN
Beam deflection 60.0 s: 0.000 µm
Measured Stiffness Modulus 60.0 s: 248.000 mPa
Estimated Stiffness Modulus 60.0 s: no data
Difference between stiffness moduli 60.0 s: no data
Estimated m-value 60.0 s: 0.378
General comments (publicly viewable) (Max 1000 characters): Test @ 0.0C

Test was verified on 10/07/2021