Summary for Test 2021-10-05-12-1

Test performed: ASTM A416-15
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only. Please click this link to view the corrected test.

Project Information

Project IdentifiersProject ID: 993111
DEA: 010L2304
EFIS: 0121000086
DIST-CO-RTE-PM01-DN-101-15.1/15.5
Award Date06/21/2021
Closeout Date12/14/2023
Work DescriptionLast Chance Grade Landslide Repair
Location DescriptionLast Chance Grade at Hwy 101 PM 15.1 to 15.5
QA Service Level1 (Verified on 07/07/2021)

Sample Information

Sample Taken Date10/05/2021 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/05/2021
Sample typeQuality Assurance A brief description of the sample.6in Prestressing Strand
The quantity of what the sample constitutes49 From where was the sample collectedManufacturer
First name of sampler or witnessed byDon Last name of sampler or witnessed byHiranaga
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s) Number of Coils
Group Number10983 Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0224548, S0225051, S0225050, S0225044, S0225046 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2021-10-05-12
DIME Test ID: 2021-10-05-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2021-10-07

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 10/06/2021
UTM: 120KIP
Temperature: 72 f
Extensometers: E88768
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0225048S335920-10.2176133258657.401.84bewing

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 10/7/2021

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.