Test 2021-07-14-31-5 (ASTM C191-13) Summary

Project Information
Project IdentifiersProject ID: 8801
DEA: AML-CEM
EFIS: AML-CEM
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location DescriptionNot set
Sample Information
Sample Taken Date7/14/2021 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/14/2021
Sample typeAnnual Source Testing A brief description of the sampleType II Portland Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Laboratory sample identificationCM215139
The fabricator/manufacturer/facility nameCALPORTLAND Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeCementitious BrandCalPortland
MillAsia Cement Taiwan Type of Cementitious MaterialType II Cement
Test Details
DIME Sample ID: 2021-07-14-31
DIME Test ID: 2021-07-14-31-5
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2021-10-01
Test Results

Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 09/23/2021
Type of Water Used: Type IV grade reagent water
Initial time of setting:222 min
Final time of setting:no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/01/2021