Test 2021-09-23-24-3 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 214402
DEA: 010E7704
EFIS: 0115000009
DIST-CO-RTE-PM01-HUM-101-R17.9/87.8
Work DescriptionSTRENGTHEN 2 BRIDGES.
Location DescriptionHUMBOLDT COUNTY AT SOUTH FORK EEL RIVER AND SEPARATION AND AT ARCATA OVERHEAD
Sample Information
Sample Taken Date9/23/2021 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/27/2021
Sample typeQuality Assurance A brief description of the sample3/4"x 3 3/4" A325 HDG Fastener with nut and washer
The quantity of what the sample constitutes29 assemblies From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of samplerAssociate Steel Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameCK Johnson Industries Transportation Laboratory (TL) NumberC658233
Inspector Lot Number from the Transportation Laboratory (TL) FormB9-068-21 Structure unique identifier
Structure nameunknown
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)443905AR
Heat Number(s)Bolt- 100205304 Nut- 100108514 washer- B60790 Nut Mfg. Lot Number(s)Nucor- 455273A
Washer Mfg. Lot Number(s)Prestige Stamping- E1386 Bolt SpecificationA3125 -A325 typ 1
Bolt Length(s)3 3/4" Nut SpecificationA563 Gr DH
Washer SpecificationF436 FinishHDG
Diameter/Size3/4" Bolt Mfg. Lot NumberNucor- 443905A
Rocap Test Requirement(s)yes Lubricant Requirements(s)yes
Test Details
DIME Sample ID: 2021-09-23-24
DIME Test ID: 2021-09-23-24-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-10-01
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/29/2021
UTM:450kip
Temperature:72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11455273A52718A563fsaylor

General comments (publicly viewable) (Max 1000 characters): A563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/01/2021