Test 2021-09-20-1-2 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 215486
DEA: 040A0204
EFIS: 0400000129
DIST-CO-RTE-PM04-SON-1-15-15.7
Work DescriptionCONSTRUCTION ON STATE HIGHWAY IN SONOMA COUNTY NEAR BODEGA BAY FROM 0.2 MILE SOUTH TO 0.4 MILE NORTH OF SCOTTY CREEK CULVERT.
Location DescriptionNot set
Sample Information
Sample Taken Date9/20/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/28/2021
Sample typeQuality Control A brief description of the sample5/8 x 3-1/2 a325 boilts
The quantity of what the sample constitutes95 From where was the sample collectedDistributor
First name of sampler or witnessed byOscar Last name of sampler or witnessed byVizcaino
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameSt Louis Screw and Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0145880
Heat Number(s)20378880 Nut Mfg. Lot Number(s)32805-6215177505
Washer Mfg. Lot Number(s)D9402 Bolt SpecificationA-325
Bolt Length(s)3-1/2" Nut SpecificationA563
Washer SpecificationF436 FinishMechanical B695
Diameter/Size5/8" Bolt Mfg. Lot NumberM4588
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2021-09-20-1
DIME Test ID: 2021-09-20-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-10-01
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/29/2021
UTM:450kip
Temperature:72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1132805-621517736009A563fsaylor

General comments (publicly viewable) (Max 1000 characters): A563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/01/2021