Summary for Test 2021-09-21-3-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 213598
DEA: 051F75U4
EFIS: 0518000092
DIST-CO-RTE-PM05-MON-101-R36.9/47.7
Award Date01/16/2019
Closeout Date01/11/2024
Work DescriptionCRCP, SEISMIC RETROFIT, BRIDGE WIDENING AND MEDIAN BARRIER
Location DescriptionMONTEREY COUNTY IN AND NEAR KING CITY FROM 0.4 MILE SOUTH OF WILD HORSE ROAD OVERCROSSING TO TEAGUE AVENUE
QA Service Level1 (Verified on 10/11/2018)

Sample Information

Sample Taken Date09/21/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/27/2021
Sample typeQuality Assurance A brief description of the sample1 1/2" x5 1/2" Rods, nuts and washers
The quantity of what the sample constitutesA449 Restrainer unit anchor bolts From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of samplerAssociate Steel Inspector Telephone number of sampler510-376-7155
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCable Moore Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB9-062-21 Structure unique identifier
Structure name44-0032L

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)DL1410243302 Nut Mfg. Lot Number(s)32834-201422
Washer Mfg. Lot Number(s)0514-489 Bolt SpecificationA449
Bolt Length(s)5 1/2" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1 1/2" Bolt Mfg. Lot Number
Rocap Test Requirement(s)no Lubricant Requirements(s)yes

Test Details

DIME Sample ID: 2021-09-21-3
DIME Test ID: 2021-09-21-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-10-01

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/29/2021
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1132834-201422216592A563fsaylor

General comments (publicly viewable) (Max 1000 characters): A563
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/1/2021