Summary for Test 2021-09-21-3-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 213598 DEA: 051F75U4 EFIS: 0518000092 |
---|---|
DIST-CO-RTE-PM | 05-MON-101-R36.9/47.7 |
Award Date | 01/16/2019 |
Closeout Date | 01/11/2024 |
Work Description | CRCP, SEISMIC RETROFIT, BRIDGE WIDENING AND MEDIAN BARRIER |
Location Description | MONTEREY COUNTY IN AND NEAR KING CITY FROM 0.4 MILE SOUTH OF WILD HORSE ROAD OVERCROSSING TO TEAGUE AVENUE |
QA Service Level | 1 (Verified on 10/11/2018) |
Sample Information
Sample Taken Date | 09/21/2021 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/27/2021 |
Sample type | Quality Assurance | A brief description of the sample | 1 1/2" x5 1/2" Rods, nuts and washers |
The quantity of what the sample constitutes | A449 Restrainer unit anchor bolts | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cable Moore | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-062-21 | Structure unique identifier | |
Structure name | 44-0032L |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | DL1410243302 | Nut Mfg. Lot Number(s) | 32834-201422 |
Washer Mfg. Lot Number(s) | 0514-489 | Bolt Specification | A449 |
Bolt Length(s) | 5 1/2" | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 1 1/2" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | no | Lubricant Requirements(s) | yes |
Test Details
DIME Sample ID: 2021-09-21-3
DIME Test ID: 2021-09-21-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2021-10-01
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/29/2021
UTM: 400kip
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | UNC 1-1/2 | 1.405 | 183587 | 816 | 130667 | 117958 | 165730 | A449 |
General comments (publicly viewable) (Max 1000 characters): A449
Test Graph
Source: Bluehill Data Point FileTest was verified on 10/1/2021 ✔