Summary for Test 2021-09-16-12-3

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 214919
DEA: 060U4504
EFIS: 0615000298
DIST-CO-RTE-PM06-FRE-168-18.6/T25.5
Award Date06/16/2020
Closeout Date07/29/2022
Work DescriptionCOLD PLANE AC PAVEMENT AND HOT MIX ASPHALT RESURFACING.
Location DescriptionFRESNO COUNTY NEAR PRATHER FROM 0.1 MILE EAST OF SAMPLE ROAD TO OAK CREEK ROAD
QA Service Level1 (Verified on 04/21/2020)

Sample Information

Sample Taken Date09/16/2021 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/20/2021
Sample typeAcceptance A brief description of the sampleRubberized PG64-16
The quantity of what the sample constitutes1 can From where was the sample collectedManufacturer
First name of sampler or witnessed byT Last name of sampler or witnessed bySilva
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMI Fresno Transportation Laboratory (TL) Numberc039961
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number2
Sublot number1 Asphalt Rubber Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-09-16-12
DIME Test ID: 2021-09-16-12-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2021-09-24

Test Results


Input Type: Measured
Tester's full name: Minoo Ahmadi
Date of test: 09/23/2021
Temperature: 25 C
Final Dial reading (F1): 70 mm
Ball Penetration (P1): 0 mm
Final Dial reading (F2): 73 mm
Ball Penetration (P2): 2 mm
Final Dial reading (F3): 73 mm
Ball Penetration (P3): 2 mm
Resilience 1: 30 %
Resilience 2: 29 %
Resilience 3: 29 %
Average Resilience: 29 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 9/24/2021