Summary for Test 2021-07-08-56-3
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 215656 DEA: 032G0604 EFIS: 0320000192 |
---|---|
DIST-CO-RTE-PM | 03-SAC-5736- |
Award Date | 05/26/2021 |
Closeout Date | 05/11/2022 |
Work Description | REMOVE AND REPLACE CL2 AGGREGATE BASE AND HMA (TYPE A). |
Location Description | SACRAMENTO COUNTY IN SACRAMENTO AT THE NORTHGATE MAINTENANCE STATION AT 3940 ROSIN COURT |
QA Service Level | 1 (Verified on 04/19/2021) |
Sample Information
Sample Taken Date | 07/08/2021 | Sample Unique Key | 56 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/01/2021 |
Sample type | Verification | A brief description of the sample | 1/2" RAP |
The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Supplier |
First name of sampler or witnessed by | ? | Last name of sampler or witnessed by | ? |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | George Reed Drum Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | George Reed Inc Clements Batch Plant, RAP |
---|---|---|---|
Aggregate Size | Aggregate Source | ||
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2021-07-08-56
DIME Test ID: 2021-07-08-56-3
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-09-24
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Benjamin Dreher
Date of test: 09/02/2021
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7345.7 grams
Mass of oven-dry sample in air for Sample 1: 1655.2 grams
Mass of container filled with the sample and water for Sample 1: 8353.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.558
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters): JMF 21-036
Test was verified on 9/24/2021 ✔