Summary for Test 2021-09-21-16-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 215521
DEA: 101L1204
EFIS: 1019000186
DIST-CO-RTE-PM10-MER-152-15.1/15.6
Award Date04/19/2021
Closeout Date06/27/2022
Work DescriptionINSTALL BRIDGE DECK AND CONCRETE BARRIER.
Location DescriptionMERCED COUNTY NEAR LOS BANOS FROM DELTA-MENDOTA CANAL BRIDGE TO 0.2 MILE EAST OF HIGHLINE CANAL BRIDGE
QA Service Level1 (Verified on 03/23/2021)

Sample Information

Sample Taken Date09/21/2021 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/21/2021
Sample typeQuality Assurance A brief description of the sampleLenton Couplers
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byFelipe Last name of sampler or witnessed byBarrera
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameErico Nucor Transportation Laboratory (TL) NumberC303
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerNucor Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelLenton Form Saver
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)L9830 Rebar Heat Number(s)3500008896
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-09-21-16
DIME Test ID: 2021-09-21-16-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-09-24

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 09/24/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1No. 5/16mm100.3131947103054Service Splicespaine

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.