Summary for Test 2021-07-29-42-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/29/2021 Sample Unique Key42
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/29/2021
Sample typeAggregate Prequalification Program A brief description of the sampleWashed Sand
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed byAntonio Last name of sampler or witnessed byRamirez
Title of samplerQC Technician Telephone number of sampler6613169606
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Gardner Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-42-0022::BUELLTON PIT
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2021-07-29-42
DIME Test ID: 2021-07-29-42-2
Testing Lab: Granite Construction Company - Gardner
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2021-09-17

Test Results


Number of tests: 3
Input Type: Calculated
Tester's full name: Elvin Reyes
Date of test: 07/29/2021
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 48
Sand reading (test 1): 45
Clay reading (test 2): 49
Sand reading (test 2): 44
Clay reading (test 3): 49
Sand reading (test 3): 45
Sand equivalent (test 1): 94
Sand equivalent (test 2): 90
Sand equivalent (test 3): 92
Sand equivalent before temperature correction: 72
Sand equivalent after temperature correction: 72
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/17/2021