Test 2015-10-14-1-2 (ASTM D412-06a-re13) Summary

Project Information
Project IdentifiersProject ID: 209217
DEA: 080F5404
EFIS: 0800000136
COOP: 081468
DIST-CO-RTE-PM08-RIV-91,15-0.0/13.04, 35.64/45.14
Work DescriptionSR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
Sample Information
Sample Taken Date10/14/2015 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/16/2015
Sample typeQuality Assurance A brief description of the sampleBearing Pad
The quantity of what the sample constitutes5 From where was the sample collectedFabricator
First name of sampler or witnessed byPete Last name of sampler or witnessed byEtcheverry
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameScougal Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)140971
Material/Compound/Elastomer ID140971 Samples Representing5
Description (size)6in x 20in x 20in CommentsUnknown
Description (Number of Shims)12 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)Scougal
Batch NumberNA
Test Details
DIME Sample ID: 2015-10-14-1
DIME Test ID: 2015-10-14-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension
Test Release Date: 2015-10-20
Test Results

Input Type: Calculated
Tester's full name: Brian
Date of test: 10/16/2015
UTM: no data
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness:0.071 in
Sample 1 Thickness all Within 0.003 inch?:yes
Sample 1 Ultimate Tensile:2359.6 lbf/in^2
Sample 1 Elongation (350% Min):Pass
Sample 2 Median Thickness:0.072 in
Sample 2 Thickness all Within 0.003 inch?:yes
Sample 2 Ultimate Tensile:2444.4 lbf/in^2
Sample 2 Elongation (350% Min):Pass
Sample 3 Median Thickness:0.075 in
Sample 3 Thickness all Within 0.003 inch?:yes
Sample 3 Ultimate Tensile:2872.3 lbf/in^2
Sample 3 Elongation (350% Min):Pass
Median of the Ultimate Tensile Values:2444.4 lbf/in^2
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Sample 1

Source: Partner Data Point File
Test graph for Sample 2

Source: Partner Data Point File
Test graph for Sample 3

Test was verified on 10/20/2015