Test 2021-08-19-61-7 (AASHTO T304-11) Summary

Project Information
Project IdentifiersProject ID: 214985
DEA: 04269804
EFIS: 0412000159
DIST-CO-RTE-PM04-CC-242-R0.0/R1.6
Work DescriptionPRECAST JOINTED CONC PVMT, INDIVIDUAL SLAB REPLACEMENT, HMA & RHMA.
Location DescriptionCONTRA COSTA COUNTY IN CONCORD FROM ROUTE 242/680 SEPARATION TO BUCHANAN FIELD VIADUCT
Sample Information
Sample Taken Date8/19/2021 Sample Unique Key61
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing8/19/2021
Sample typeVerification A brief description of the sample5 Bags of Aggregate
The quantity of what the sample constitutes5 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byignacio Last name of sampler or witnessed byAreihiga
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameCounty Asphalt Martinez Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-07-0003
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedCounty Asphalt Martinez
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID JMF3513-2021-77
Test Details
DIME Sample ID: 2021-08-19-61
DIME Test ID: 2021-08-19-61-7
Testing Lab: CT D04 - DME / District Lab
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2021-09-15
Test Results

What test method is performed?: Method A
Input Type: Measured
Tester's full name: David Ordaz
Date of test: 08/19/2021
Mass of measure: 250.8 grams
Bulk dry specific gravity: 2.615
Mass of sample and measure #1: 396.3 grams
Mass of sample and measure #2: 396.4 grams
Volume of cylinder: 100.3 mL
Mass of sample #1: 145.5 grams
Mass of sample #2: 145.6 grams
Uncompacted voids #1: 44.5 %
Uncompacted voids #2: 44.5 %
Average uncompacted voids:44.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 09/15/2021