Test 2021-08-13-35-2 (AASHTO T283-14) Summary

Project Information
Project IdentifiersProject ID: 215605
DEA: 040W3904
EFIS: 0420000212
DIST-CO-RTE-PM04-CC-160-L1.1/0.6
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE HMA (A).
Location DescriptionCONTRA COSTA COUNTY IN ANTIOCH FROM 0.2 MILE SOUTH OF MAIN STREET TO 0.1 MILE NORTH OF WILBUR AVENUE
Sample Information
Sample Taken Date8/13/2021 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/13/2021
Sample typeVerification A brief description of the sample25 Boxes-Hot Mix Asphalt
The quantity of what the sample constitutes25 Boxes-Hot Mix Asphalt From where was the sample collectedManufacturer
First name of sampler or witnessed byClint Last name of sampler or witnessed byRogers
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameABM ANTIOCH Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number JMF Verification ID JMF3513-2021-76
Test Details
DIME Sample ID: 2021-08-13-35
DIME Test ID: 2021-08-13-35-2
Testing Lab: CT D04 - DME / District Lab
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2021-09-09
Test Results

Input Type: Calculated
Tester's full name: Trevor Hamilton
Date of test: 08/24/2021
Specimen Treatment: Treated
Average Dry Tensile Strength: 197 psi
Average Wet Tensile Strength: 159 psi
Tensile Strength Ratio:0.81
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 09/09/2021