Summary for Test 2021-08-13-35-2
Test performed: AASHTO T283-14Project Information
Project Identifiers | Project ID: 215605 DEA: 040W3904 EFIS: 0420000212 |
---|---|
DIST-CO-RTE-PM | 04-CC-160-L1.1/0.6 |
Award Date | 05/10/2021 |
Closeout Date | 06/29/2023 |
Work Description | COLD PLANE AC PAVEMENT AND PLACE HMA (A). |
Location Description | CONTRA COSTA COUNTY IN ANTIOCH FROM 0.2 MILE SOUTH OF MAIN STREET TO 0.1 MILE NORTH OF WILBUR AVENUE |
QA Service Level | 1 (Verified on 04/12/2021) |
Sample Information
Sample Taken Date | 08/13/2021 | Sample Unique Key | 35 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/13/2021 |
Sample type | Verification | A brief description of the sample | 25 Boxes-Hot Mix Asphalt |
The quantity of what the sample constitutes | 25 Boxes-Hot Mix Asphalt | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Clint | Last name of sampler or witnessed by | Rogers |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | ABM ANTIOCH | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-08-13-35
DIME Test ID: 2021-08-13-35-2
Testing Lab: CT D04 - Hayward DME / District Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2021-09-09
Test Results
Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Trevor Hamilton
Date of test: 08/24/2021
Specimen Treatment: Treated
Average Dry Tensile Strength: 197 psi
Average Wet Tensile Strength: 159 psi
Tensile Strength Ratio: 0.81
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/9/2021 ✔