Summary for Test 2021-08-31-2-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 213099
DEA: 041A6614
EFIS: 0415000291
COOP: 042683A1
DIST-CO-RTE-PM04-MRN-101-8.4
Award Date11/30/2020
Closeout Date12/12/2023
Work DescriptionCONSTRUCTION ON STATE HIGHWAY IN MARIN COUNTY IN LARKSPUR
Location DescriptionNot set
QA Service Level1 (Verified on 11/06/2020)

Sample Information

Sample Taken Date08/31/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing09/07/2021
Sample typeQuality Assurance A brief description of the sample#5 Lenton Threaded Bar Couplers
The quantity of what the sample constitutesLot 4 From where was the sample collectedFabricator
First name of sampler or witnessed byPaul Last name of sampler or witnessed byShrestha
Title of samplerQA Inspector Telephone number of sampler(424)298-7781
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCamblin Steel Service Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL108-010-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A615
Material Grade60 Rebar ManufacturerVinton Steel
Coupler ManufacturerErico International Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelLenton Form Saver
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)202040/9830 Rebar Heat Number(s)2121471, 2121499, 2121500
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-08-31-2
DIME Test ID: 2021-08-31-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-09-09

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/09/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13No. 5/16mm400.3132536104956Service Splicefsaylor

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 9/9/2021