Summary for Test 2021-08-27-3-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 214995 DEA: 040J5304 EFIS: 0414000010 |
---|---|
DIST-CO-RTE-PM | 04-ALA-880-11.4/12.2 |
Award Date | 01/04/2021 |
Closeout Date | 04/26/2023 |
Work Description | PATTERSON SLOUGH BRIDGE DECK REHAB |
Location Description | ALAMEDA COUNTY IN FREMONT FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF PATTERSON SLOUGH BRIDGE |
QA Service Level | 1 (Verified on 10/19/2020) |
Sample Information
Sample Taken Date | 08/27/2021 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/01/2021 |
Sample type | Quality Assurance | A brief description of the sample | Lennton A2 |
The quantity of what the sample constitutes | x | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Sherri | Last name of sampler or witnessed by | Brannon |
Title of sampler | QA Inspector | Telephone number of sampler | 916-826-6371 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | C and N Reinforcing | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B22-074-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Cascade Steel |
Coupler Manufacturer | Lenton | Intermediate Assembler or Fabricator | C and N Reinforcing |
Rebar Size | #11 | Coupler Model | A2 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | A180950 | Rebar Heat Number(s) | 149821 |
Rebar Size 2 | 11 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2021-08-27-3
DIME Test ID: 2021-08-27-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-09-07
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/03/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID: Small
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 1 | No. 11/36mm | 1 | -0.0038 | 1.56 | 139249 | 89262 | Service Splice | bewing |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 9/7/2021 ✔