Summary for Test 2021-08-31-9-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 215231 DEA: 042A3324 EFIS: 0414000039 |
---|---|
DIST-CO-RTE-PM | 04-ALA-84-10.8/18 |
Award Date | 02/22/2021 |
Closeout Date | 02/29/2024 |
Work Description | NILES CANYON SAFETY PROJECT |
Location Description | ALAMEDA CREEK BR OH (33-0034) BRIDGE RAIL REPLACEMENT, 2,060 LF; AND STONYBROOK CREEK BRIDGE (SLAB BRIDGE) |
QA Service Level | 1 (Verified on 10/19/2020) |
Sample Information
Sample Taken Date | 08/31/2021 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/03/2021 |
Sample type | Quality Assurance | A brief description of the sample | #5 with A2 Lenton Couplers |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Carpenter |
Title of sampler | QA | Telephone number of sampler | 14156081742 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Conco Reinforcing | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B24-071-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | Eaton | Intermediate Assembler or Fabricator | |
Rebar Size | #5 | Coupler Model | A2 Lenton |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | 8298701 | Rebar Heat Number(s) | 3500019909 |
Rebar Size 2 | 5 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2021-08-31-9
DIME Test ID: 2021-08-31-9-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-09-07
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/02/2021
UTM: 400kip
Temperature: 72.00 f
Halo ID:
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 2 | No. 5/16mm | 0051 | 0 | 0.31 | 29802 | 96137 | Service Splice | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 9/7/2021 ✔